.TH SDORION 3 .SH NAME sdorion \- Marvell Orion II SAS/SATA drivers .SH SYNOPSIS .nf .B bind -a #S /dev .sp 0.3v .BI /dev/sdctl .sp 0.3v .BI /dev/sd a 0/ctl .BI /dev/sd a 0/raw .BI /dev/sd a 0/data .BI /dev/sd a 0/led \&... .fi .SH DESCRIPTION The .I sdorion driver provides access to SAS, SATA and ATAPI devices via the .IR sd (3) interface. The Orion programming interface supports up to 16 hot-swappable devices per controller. .PP Orion controllers are detected automatically. Currently only the Marvell 6485 is supported, although devices using the Marvell 6420, 6440 and 6480 chipsets can likely be supported with minimal changes. .PP The top level control file, .BR /dev/sdctl , supports the following control messages for .IR sdorion : .TF "\fLorion idprint" .TP .B orion debug Toggle debug messages. Default is off. .TP .B orion idprint Toggle printing of drive identification messages. Default is on. Prints short messages when a drive is identified or removed. .TP .B orion aprint Print verbose ATAPI debugging messages. Default is off. .PD .PP The device-level .B ctl file supports: .TF \fLnopower .TP .BI "state " state Force a transition to the named .IR state . The states are: .RS .TF portreset .TP .B null ignored (may only be reached manually); .TP .B missing not detected; .TP .B nopower detected in power-saving state; .B new newly discovered; .TP .B ready ready for commands; .TP .B error not ready for commands due to error; .TP .B reset being reset gently; .TP .B portreset being fully reset; .TP .B offline device failed .B portreset (a port reset will be attempted periodically). .RE .PD .PP For devices present at boot, the transition is from state .B new to state .BR ready . .PP The .B led file allows the external control of enclosure LED states through SES-2 messages over GPIO/SFF-8485. I²C transport is not supported. The contents of the .B led file is the current state of the port's LEDs. Writing a state to the file will set the given state. The Orion does not set LED states and slots without drives may not be controlled. The standard SES states accepted are .TF \fLnormal .TP .B none no state set; .TP .B normal nominal condition; .TP .B rebuild parent lun is rebuilding; .TP .B locate show drive location; .TP .B spare hot spare drive; .TP .B fail drive has failed and should be replaced. backplane buzzer will sound. .PD .PP The LED state has no effect on drive function. .SH SOURCE .B /sys/src/9/pc/sdorion.c .SH SEE ALSO .IR atazz (8), .IR scuzz (8), .IR sd (3), SES-2 (ANSI INCITS 305-1998) .SH BUGS Enclosure management, port multipliers and SAS expanders are not supported. Commands that take too long to complete will be timed out; .L "security erase unit" is almost certain to time out.